Automated Visual Field Analyzer

Automated Visual Field Analyzer

The BIO-1000 automated visual field analyzer is a static perimeter designed to provide accurate and speedy diagnosis and monitoring of visual nerve diseases and glaucoma. Based on the International Goldmann standard design, the product is developed to offer crucial inspection modes for patients and provide them with optimal visual care.
Send Inquiry
Description
Technical Parameters

 

BIO-1000 AUTOMATED VISUAL FIELD ANALYZER

 

The BIO-1000 automated visual field analyzer is a static perimeter designed to provide accurate and speedy diagnosis and monitoring of visual nerve diseases and glaucoma. Based on the International Goldmann standard design, the product is developed to offer crucial inspection modes for patients and provide them with optimal visual care.

 

Multiple fixation monitoring programs ensure high reliability.

Comprehensive real-time monitoring includes Heijl-Krakau physiological blind spot monitoring, gaze tracking, head position tracking, and automatic measurement of pupil diameter, reducing the impact of pupil effects on visual field detection.

 

Abundant inspection modes ensure both accuracy and speed.

Rich threshold and suprathreshold inspection modes detect early visual field defects.
The scientific and intelligent interactive inspection strategy improves work efficiency, completing a 30° field of view inspection in just 3 minutes.

 

Comprehensive Analysis Software:

Six types of analysis: reliability analysis, single-report analysis, multi-report analysis, glaucoma half-field analysis, glaucoma progression analysis, and VFI (Visual Field Index) analysis.
Half-field analysis designed for glaucoma facilitates easier diagnosis.
Analysis of glaucoma progression enhances visibility of subtle changes and provides ongoing progression alerts.

 

 

 

Hot Tags: automated visual field analyzer, China automated visual field analyzer manufacturers, suppliers, factory

Specifications:

Inspection range

90°

Inspection distance

30CM

Background light brightness

White 31.5asb

Visual target brightness

0asb-10000asb

Visual target size

Goldmann III

Visual target interval time

200ms (Standard or adjustment according to patient reflection)

Light source

LED

Threshold test model

Center 5°-16, center 10°-68, 24-2, 30-2, 30°-60°, nasal step

Upper Threshold test model

30°-40, 30°-76, P-60, 60°-81, 60°-120, 90°-135 nasal side

Special detection strategy

Esterman monocular, Esterman binoclular, user-customized test, 150° driver monocular fast detection, 150° driver monocular standard detection, upper 36° detection, blind spot detection, 150° horizontal straightness detection

Pupil size test

Automatic

Fixation monitoring

Blind spot monitoring, eye position deviation alarm, eye deviation curve

Environment light detection

Automatic

Analysis software

Reliability analysis, single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis

Operation system

Window 7 above

Power

100-240V, 50/60HZ

Dimension

412*497*513mm(L*W*H)

Weight

17KGS